ps-1
Overview
title
Produkt Details
SKU
904003
Name
JUMO plastoSENS T03
Description
The JUMO plastoSENS T03 solves the problem of insufficient leak-tightness from conventional probes. Since the special plastics used in the injection molding process form an adhesive bond, it is completely sealed, even at the critical point of the cable outlet – ideal for sterilization applications.
Short Description
Steam-tight plastic temperature probe
Price
€0.00
Availability
In Stock
Images
State
LIVE
cf-data
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
title
Icon
icon-shield
Description
Absolute leak-tightness
Icon
icon-check
Description
Steam-tight even at cable outlet location
Icon
icon-thermometer
Description
Redundant measurement due to the use of 2 sensing elements
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=868788
Temperature
-50 to +200 °C
Protection type
IP69K
Application areas
Autoclaves, steam sterilizers, CIP cleaning, SIP cleaning
Protection tube
Probe is completely enclosed with special plastic
Special features
Steam-tight even at the cable outlet point, absolute leak-tightness due to injection molding process, redundant measurement due to the use of 2 sensing elements