ps-1
Overview
title
Produkt Details
SKU
902520
Name
RTD temperature probes
Description
Indoor, wall, and outdoor RTD temperature probes for air conditioning technology are mainly used to measure temperature in rooms, halls, and outdoors. Various device versions made of plastic with different protection types are available for the respective measuring task.
Short Description
for indoors, walls, and outside
Availability
In Stock
Images
State
LIVE
Variants
Measuring insert
- 1x Pt100 in 2-wire circuit ✓
- 1x Pt100 in 3-wire circuit ✓
- 1x Pt1000 in 2-wire circuit ✓
- 2x Pt100 in 2-wire circuit ✓
Operating temperature in °C
- -20..80°C ✓
- -30..80°C ✓
- -30..90°C ✓
- -40..+80°C (range only in connection with transmitter) ✓
- -50..90°C ✓
- 0..40°C (range only in connection with extra code 330 or 333) ✓
- 0..60°C (range only in connection with extra code 330 or 333) ✓
Basic type
- Indoor and outdoor resistance thermometer with stepped protection tube, Protection class IP65 ✓
- Indoor and outdoor resistance thermometer, Protection class IP54 ✓
- Indoor resistance thermometer, protection class IP20 ✓
- Outdoor resistance thermometer, Protection class IP65 ✓
- Wall resistance thermometer with inner sensor protection IP65 ✓
- Wall resistance thermometer with outer sensor protection IP65 ✓
- wall resistance thermometer with stepped protection tube protection IP65 ✓
Extra code 903
Extra code transmitter
cf-data
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
title
Icon
icon-flow-tree
Description
Two-wire, three-wire, or four-wire circuit
Icon
icon-check
Description
Analog transmitter available
Icon
icon-shield
Description
SIL and PL compatible
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=4464
Option
Head transmitter
Features
Wall mounting
Areas of application
Facility management, combined heat and power plants
Measuring circuits
1/2
Approvals
SIL, PL
Protection type
IP65
Operating temperature
-50 to +90 °C
Sensor
Pt100, Pt1000, Ni1000
Connection
Terminal case
ps-2
Downloads
title
Downloads
ps-3
Accessories
title
Accessories
Are you looking for support?
We will assist you with your project and provide you with an offer tailored to your personal needs.
We care about your problems and will find solutions for you. We are also the contact persons for startup