ps-1
Overview
title
Produkt Details
SKU
902524
Name
RTD temperature probes
Description
Channel RTD temperature probes for air conditioning technology are predominantly used for temperature measurement in air channels and outdoors. Various device versions made of plastic with different protection types are available for the respective measuring task.
Short Description
for channel mounting
Availability
In Stock
Images
State
LIVE
Variants
Diameter prot. tube
Measuring insert
Nominal length
- 1.000000000000000E+02 ✓
- 1.500000000000000E+02 ✓
- 125,0 ✓
- 155,0 ✓
- 175,0 ✓
- 2.000000000000000E+02 ✓
- 225,0 ✓
- 325,0 ✓
- 450,0 ✓
- 75,0 ✓
Operating temperature in °C
Basic type
- Channel resistance thermometer with plain protection tube, Protection IP54 ✓
- Push-in channel resistance thermometer, permanent protection tube, ambient temperature housing -30 to +90 °C protection IP65 ✓
Extra code 310
- Protection tube stepped down from Ø 6 mm to Ø 3,3 mm (not in connection with measuring insert 2x xxx) ✓
- Without extra code ✓
Extra code 404
Extra code transmitter
cf-data
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
title
Icon
icon-cart
Description
Transmitter available
Icon
icon-check-all-alt
Description
Different temperature sensors possible
Icon
icon-shield
Description
SIL and PL compatible
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=4464
Sensor
Pt100, Pt1000, Ni1001, KTY 81-110, LM235, NTC 1 kOhm
Areas of application
Facility management, air heaters
Protection type
IP65
Operating temperature
-50 to +200 °C
Measuring circuits
1/2
Protection fitting
Stainless steel
Process connection
Sheet flange, pipe screw connection G 1/4, 3/8, 1/2, M20 × 1.5, 1/2-14 NPT
Features
Channel mounting
Approvals
SIL, PL
Option
Head transmitter
Connection
Terminal case
ps-2
Downloads
title
Downloads
ps-3
Accessories
title
Accessories
Are you looking for support?
We will assist you with your project and provide you with an offer tailored to your personal needs.
We care about your problems and will find solutions for you. We are also the contact persons for startup