Name
JUMO diraVIEW 104/108/116/132
Description
Devices that can be used universally in various DIN formats to display process variables. The basic version includes a min/max value function, a hold function, a taring function, limit value monitoring functions, digital control signals, timer functions, and a service counter.
Short Description
Digital indicator
Availability
In Stock
Images
State
TOP_SELLER
Variants
Option 2
Basic type
- JUMO diraVIEW 104 (size 96x96 mm, 1x analog input, 2x relay, 1x DI, 1x DI/DO) ✓
- JUMO diraVIEW 108 (size 96x48 mm, 1x analog input, 2x relay, 1x DI, 1x DI/DO) ✓
- JUMO diraVIEW 116 (size 48x48 mm, 1x analog input, 2x relay, 1x DI, 1x DI/DO) ✓
- JUMO diraVIEW 132 (size 48x24 mm, 1x analog input, 1x relay, 1x DI, 1x DI/DO) ✓
Voltage supply
cf-data
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
title
Icon
icon-keyboard
Description
Creation of individual ST code application
Icon
icon-monitor
Description
Intuitive configuration and operation
Icon
icon-sun
Description
Fast and simple startup
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=515742
Display
18-segment LCD display, display elements for switch position of the outputs and timer, pixel matrix LCD display (only type diraVIEW 108 and diraVIEW 104)
Inputs
1 user configurable analog input for RTD temperature probes, thermocouples, current 0(4) to 20 mA, voltage 0(2) to 10 V, resistance transmitters, resistance/potentiometers
Outputs
701510: 1 relay 3 A/230 V AC (normally open contact), 1 logic output 0/14 V (alternatively to digital input 1); 701511: 2 relay 3 A/230 V AC (normally open contact), 1 logic output 0/14 V (alternatively to digital input 1); optionally: analog output, relay; 2 relay 3 A/230 V AC (normally open contact), 1 logic output 0/14 V (alternatively to digital input 1); optionally: analog output, relay, PhotoMOS® relay
Digital inputs
2 digital inputs for potential-free contacts (digital input 1 alternative to logic output)
Calibration accuracy
0.1 %; 0.25 %
Galvanic isolation
3000 V (measurement input for supply)
Special features
Math and logic functions, ST code programming, min/max value memory and display, hold function, service and operating hours counter, tare function for weighing applications
Formats
132: 48 × 24 mm; 116: 48 × 48 mm; 108H: 48 × 96 mm; 108Q: 96 × 48 mm; 104: 96 × 96 mm
Installation
Panel cut-out or DIN rail adapter
Interfaces
Setup interface (USB powered), RS485 interface (optional)
Ambient temperature
-10 to +55 °C
Alarms
4 × limit value monitoring function
Connections
Spring-cage terminals, PUSH IN terminal technology
Protection type
IP65
Voltage supply
AC/DC 20 to 30 V, AC 110 to 240 V