Description
The exhaust gas temperature monitor is used to monitor the exhaust gas temperature released from solid fuel boilers when in bivalent operation with oil-fired boilers. Another application is the locking of ventilation systems that cause vacuums in combination with tiled stoves and chimneys.
Short Description
Type STM-RW-2
Availability
In Stock
Images
State
LIVE
cf-data
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
title
Icon
icon-mouse
Description
Microswitch
Icon
icon-reload
Description
Automatic reset
Icon
icon-shield
Description
High level of contact reliability
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=5071
Admissible ambient temperature
At the probe: max. 700 °C; at the switching head: max. 80 °C, min. -50 °C
Time constant
Flue gas ≤ 45 sec.
Process connection
"DZ" G 1/2 (fixed hexagon with external thread G 1/2), material: steel
Protection type
IP54
Housing material
Aluminium die-cast, surface with impact-resistant textured paint
Limit value range
40 to 120 °C (default setting to 100 °C); 20 to 400 °C (default setting to 120 °C)