ps-1
{{overviewsectiontitle}}
title
Produkt Details
SKU
709061
Name
JUMO TYA 201
Description
Thyristor power controllers are used where larger resistive and inductive loads have to be switched (e.g. in industrial furnace construction and plastics processing). It consists of 2 antiparallel switched thyristors, the insulated heat sink, and the control electronics.
Short Description
Single-phase thyristor power controller
Availability
In Stock
Images
State
LIVE
Variants
cf-data
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
title
Icon
icon-computer
Description
LCD display with info line
Icon
icon-usb
Description
Setup program via USB interface
Icon
icon-stacks
Description
Close mounting possible
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=10328
Subordinate control loop
U, U2 control (as a standard feature); I, I2, P control (optional)
Load type
Resistive load, resistive inductive load, cold/warm ratio 1:16, transformer load, infrared emitter (short, medium, long-wave)
Load voltage
24 V, 42 V, 115 V, 230 V, 400 V, 460 V, 500 V
Load currents
20 A, 32 A, 50 A, 100 A, 150 A, 200 A, 250 A
Approval
cULus
Special features
Current limiting, mains load optimization, dual energy management, "Teach-In" function (partial load failure detection), "r-control" (resistance limitation), intelligent diagnosis system, integrated semiconductor fuse, device configuration without auxiliary voltage, vibrant display, "True RMS" (root mean square)
Control voltage
Control voltage = load voltage
Operating modes
Phase-angle control, burst-firing operation; half-wave control; SSR logical operation; fast logical operation, alpha start; soft start
Ambient temperature
-20 to +70 °C
System interfaces
Modbus, PROFIBUS DP, system bus JUMO mTRON T, EtherCAT, PROFINET
Configuration
Setup/USB-powered; plain text display on the device