ps-1
Overview
title
Produkt Details
SKU
901006
Name
Thermocouples
Description
Screw-in thermocouples are predominantly used for measuring temperature in liquids and gases. Protection tubes made of various materials protect the measuring insert against chemical influences and mechanical damage.
Short Description
For devices and plants tested according to DIN EN 14597
Availability
In Stock
Images
State
LIVE
Variants
Part number
cf-data
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
title
Icon
icon-thermometer
Description
Single or double thermocouple
Icon
icon-book-checked
Description
Use in plants according to DIN 4754
Icon
icon-check
Description
For the media water, oil, or air
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=4966
Special features
Protection tubes made from various materials
Operating temperature
-35 to +1500 °C
Protection fitting
Stainless steel 1.4571, steel 1.0305, ceramic KER 710, sheath cable Inconel 600 2.4816
Approvals
DIN EN 14597, DIN 4754
Thermopairs
B, K, L, S
Process connection
G 1/2
Insertion length
50 to 5000 mm
Terminal heads
Form B DIN 43729
Option
Adjustable stop flange, weld-in sleeve, compression fitting, push-in mineral-insulated thermocouples with compensating cable
Areas of application
Heating, furnace, and apparatus engineering; tested control and limitation devices
ps-2
Downloads
title
Downloads
ps-3
Accessories
title
Accessories
Are you looking for support?
We will assist you with your project and provide you with an offer tailored to your personal needs.
We care about your problems and will find solutions for you. We are also the contact persons for startup