ps-1
Overview
title
Produkt Details
SKU
907021
Name
Hygro transducer, hygrothermal transducer, and CO2 measuring probe
Description
This measuring probe is mainly used in heating engineering, air-conditioning, and ventilation technology. It sets itself apart in particular through high measuring accuracy, long-term stability, and chemical resistance.
Short Description
For facility management and climate monitoring
Availability
In Stock
Images
State
LIVE
Variants
Version
- CO2 (channel 1 output) ✓
- CO2 and temperature (channel version, only for 0 up to 10 V) ✓
- CO2 and temperature (T passive) ✓
- CO2, temperature and humidity (only for 0..10V) ✓
- Humidity (channel 1 output) ✓
- Humidity and temperature ✓
Output
- 0 to 1 V / 0 to 1 V ✓
- 0 to 10 V / 0 to 10 V / ( 0 to 10 V ) ✓
- 4 to 20 mA / 4 to 20 mA ✓
- 4 to 20 mA / temperature passive Pt1000 class A ✓
Range(s)
- 0..100% rH/ -20..+80°C ✓
- 0..100% rH/ -40..+60°C ✓
- 0..100% rH/ 0..+50°C ✓
- 0..2000ppm/ 0..50°C/ 0..100% rH ✓
- 0..5000ppm/ 0..50°C/ 0..100% rH ✓
Basic type
- CO2 measuring probe channel version ✓
- CO2 measuring probe room version ✓
- CO2 measuring probe wall version ✓
- Hygro-/hygrothermal transducer channel version ✓
- Hygro-/hygrothermal transducer channel version (HKL) ✓
- Hygro-/hygrothermal transducer duct model (version A) ✓
- Hygro-/hygrothermal transducer duct model (version B) ✓
- Hygro-/hygrothermal transducer wall model (version B) ✓
- Hygro-/hygrothermal transducer wall version ✓
- Hygro-/hygrothermal transducer wall version (HKL) ✓
- Hygro-/hygrothermal transducer, indoor model ✓
- Hygrothermal transducer rod version with 1,5 m connecting cable ✓
Extra code 793
cf-data
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
title
Icon
icon-computer
Description
LCD display
Icon
icon-wranch
Description
Indoor, wall-mounted, duct, and rod versions
Icon
icon-anschluesse
Description
Current, voltage, or Modbus output
title
Technical data
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=4049
Outputs
4 to 20 mA, 0 to 1 V, 0 to 5 V, 0 to 10 V, and Pt100/Pt1000 (with T passive)
Application
Building automation, storerooms, air conditioning and ventilation control systems
Version
Indoor, duct, wall-mounted, and rod version
CO2 sensing element
NDIR method (non-dispersive infrared technology)
Protection type
IP20 indoor version; IP65 wall-mounted, duct, and rod version
Humidity sensing element
Capacitive (resistant to condensation, fast response)
Ambient temperature
-20 to +60 °C (indoor version, wall-mounted and duct version, CO2), -5 to +55 °C (indoor version with LCD display), -15 to +60 °C (wall-mounted and duct version, HVAC), -40 to +60 °C: rod version, wall-mounted and duct version (-20 to +50 °C with LCD display)
Measuring range
CO2 = 0 to 2000/5000/10000 ppm, T = 0 to 50 °C (scaling active with analog output), RH = 0 to 100 % RH
Accessories
Replaceable filters available as accessories
Measurement medium
Air, pressureless sensor coating permits measurements in numerous aggressive media (exception: indoor version)
Voltage supply
DC 24 V (standard), others depending on the version
Temperature range
0 to 50 °C (indoor version; wall-mounted and duct version, HVAC, and CO2), -40 to +80 °C (wall-mounted and duct version, rod version with Modbus output), -40 to +60 °C (rod version)
ps-2
Downloads
title
Downloads
ps-3
Accessories
title
Accessories
Are you looking for support?
Inquiries/Offers
We will assist you with your project and provide you with an offer tailored to your personal needs.