{{request_inquiry}}
#
ps-1
Overview
title
Produkt Details
SKU
709020
Name

JUMO TYA 432

Description
Thyristor power switches are required for contactless switching of the alternating current loads. A typical application is the switching of resistive inductive loads at a high switching frequency, particularly in the industrial sector.
Short Description
Thyristor power switch
Availability
In Stock
Images
  • JUMO TYA 432
State
LIVE
Variants

Version

Load current

Basic type

Mains voltage

cf-data
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
title
Icon
icon-snowflake
Description
With heat sink
Icon
icon-check
Description
UL approval
Icon
icon-pause
Description
Control/power section galvanically isolated
title

Technical data

datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=4612
Peak blocking voltage
1600 Vs; 1200 Vs
Ambient temperature
-40 to +70 °C
Galvanic isolation
Between the control and power section through optocouplers; insulation voltage 4 kV
Load current (max.)
60 A (at 40 °C)
Operating mode
Zero point control
Load voltage
24 to 265 V AC; 42 to 660 V AC
Approval
cULus/CSA
Protection type
IP20
Control voltage
Œ4 to 32 V DC; 5 to 32 V DC
ps-2
Downloads
ps-3
Accessories
title

Accessories

Are you looking for support?

Customer service

We care about your problems and will find solutions for you. We are also the contact persons for startup
Team Service
France JUMO
+33 3 87 37 53 00
Contact us now!