ps-1
Áttekintés
title
Produkt Details
SKU
405056
Name
JUMO DELOS S02
Description
The device is used to acquire relative and absolute pressures in liquid and gaseous media. The measuring ranges are between 0.1 to 100 bar relative or 0.4 to 60 bar absolute. In addition to high process reliability and a rotatable housing, the JUMO DELOS S02 stands out with its real-time data transmission via Single Pair Ethernet or IO-Link interface. The intelligent pressure sensor is configured via Bluetooth with the JUMO smartCONNECT app.
Short Description
Innovative precision pressure transmitter with display
Price
€0.00
Availability
In Stock
Images
State
NEW
cf-data
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
title
Icon
icon-compose
Description
Simple configuration
Icon
icon-shield
Description
High degree of process reliability
Icon
icon-red-check
Description
High degree of accuracy
title
Műszaki adatok
datasheet
https://www.jumo.net/attachments/JUMO/attachmentdownload?id=1243035
Inputs
0.1 to 100 bar relative, 0.4 to 60 bar absolute
Outputs
2× PNP switching output; 1× PNP switching output and 1× analog output (optional: 4 to 20 mA, 0 to 10 V); Single Pair Ethernet (SPE) with PoDL (Modbus TCP slave); 1× PNP switching output and IO-Link
Operation
Configuration via Bluetooth/smartphone app or IO-Link possible
Display
Measured value, diagnostic information, connection status
Special features
Direct cloud connection possible, rotatable display, maximum accuracy and long-term stability
title
Ügyfélelőnyök áttekintése
benefit
Minimal cabling effort when using the digital interfaces (IO-Link/SPE)
benefit
Easy configuration via Bluetooth/smartphone app or IO-Link
benefit
Optimum readability due to any installation position